Features:
 | 110V AC Input |
The Activator can use 110V AC for a power source.
 | Current Adjust Knob |
Controls the current. Turning the knob clockwise increases the
current flow. Begin each charge with the current turned down.
 | Mode Select |
Before charging, use the Mode Select to select the regular charging
mode or the Slow Peak Mode. During charging, the Mode Select chooses
what will be viewed in the digital screen.
 | Amp Display |
During charging, push the Mode Select until the AMP LED glows. Use
the current adjust knob to select the desired charge rate.
 | Voltage Display |
To display the output voltage during charging, push the Mode Select
until the green LED for the Volt glows. As the battery charges, the
voltage will increase. Once the voltage stops increasing and then begins
to decrease, the charger will sense the peak and switch to trickle
charge. The voltage displayed is a function of the charger output. It is
not the exact voltage of the battery and should be used for reference
only.
 | Glow Adaptor |
The Activator will charge your glowplug ignitor such as the Magnum
Ni-Starter. Connect the adaptor to the output plug. Then use the custom
ni-starter adaptor to connect the Ni-Starter.
 | Start Button |
Connect the power input, connect the battery, turn the current to
low, select the charge mode, then press the Start Button to begin
charging
 | Peak Volt Display |
Displays the top voltage reached during the charge. During charging,
push the Mode Select until the center LED lights up. This function
memorizes the high voltage attained during the charge and remembers it
after the charge is finished. The memory is cleared when the battery
pack is removed.
 | Peak Time Display |
Displays the time taken to complete the charge. During charging, push
the Mode Select until the Time Led lights up. This function memorizes
the time used to reach the peak charge and remembers it after the charge
is finished. The memory is cleared when the battery pack is removed.
 | .2A SP Display Slow Peak |
The slow peak charge function is designed for small (150mah and
under) batteries. Use the Mode elect to choose the slow peak function
(furthest left and right LED will light up at the same time.) The Slow
Peak function must be selected before the charge has started.
 | Charge Indicator |
When the charger is ready to be used, the charge light will blink
slowly. During the initial charge test, the light will flash,
alternating with the test light. During regular charge, the light will
stay steady. Once the battery has reached peak, the light will flash
quickly.
 | Test Indicator |
Once the Start Button has been pushed, the test light and the charge
light will flash until the charger has deemed the battery ready for
charge.
 | Tone |
Once the battery reaches peak, an audible tone sounds to let the user
know the battery is fully charged.
 | Trickle |
Once the battery reaches peak, the Activator automatically switches
to a slow l00mah charge.
 | 10A Fuse |
The charger is fuse protected. If the fuse blows (fails) test the
charger and battery for improper connection. Replace the fuse only with
a 10A fuse. Do NOT bypass the fuse.
|